Specification:
Power Input:
Ø
DC input: -36Vdc ~ -72Vdc which is provided from
backplane
Ø
Power consumption: less than 20 Watts per
cards
Ø
Connector: Via DIN64
connector from backplane
Remote power feeding:
Ø Output
Voltage 200Vdc ~ 300Vdc
Ø
Feeding
current: < 60mA
CPE Power input:
Ø
Line
code: TC-PAM
Ø
Power
Consumption: max 10 watt
SHDL
Interface:
Ø
Line code: TC-PAM
Ø
Transmission rate: up to 2.3M
Ø
Range: up to 6.0 km at 0.4mm copper wire(depended
on rate)
Ø
AC
impedance: 135 ohm
Ø
Meet
ITU-T G.991.2, ETSI TS 101 524 and ANSI T1.422 requirements
Ø
Connector: Wire wrap pins (rear access)
LPTOS (POTS on LU)
Interface:
Ø
Ringing
detection: 16 ~ 60 Hz, > 40 Vrms
Ø
Metering
pulse detection: 12/16KHz, > 10dBm (LCPOTS only)
Ø
Battery reversal
detection delay: < 40mS (LCPOTS only)
Ø
AC
impedance: 600 ohm (900 ohm for customer requirement)
Ø
Encoding: A
law (meet ITU-T G.711 requirements)
Ø
VF
parameter: meet ITU-T G.712 requirements
Ø
On
hook data transmission delay: < 50mS
Ø
Connector:
Wire wrap pins (rear access)
RPTOS (POTS on RT)
Interface:
Ø
Loop resistance:
1.2kohm (including phone-set)
Ø
Ringing
generation: >50Vrms, 25 ± 1
Hz
Ø
Open circuit
voltage: 48Vdc
Ø
Metering
pulse generation: 12/16KHz, >-2.5dBm
Ø
AC
impedance: 600 ohm (900 ohm for customer requirement)
Ø
Encoding: A
law (meet ITU-T G.711 requirements)
Ø
VF
parameter: meet ITU-T G.712 requirements
Ø
On hook data
transmission delay: < 50mS
Ø
Connector:
Terminal Block (Pluggable Rising Clamp Type)
Ethernet Interface:
Ø
Meet IEEE
802.3 requirements
Ø
10/100M auto
negotiation
Ø Support
half and full duplex
Ø AC
impedance: 100 ohm
Ø
Loop reach:
100m@(Cat5 or above)
Ø
Connector:
RJ-45 (front access)
Operation Environmental Conditions: (CPE)
Ø
Temperature: 0 ~ 60°C
Ø
Humidity: 5 ~ 95 %(RH)
Operation Environmental Conditions: (indoor version,
LU)
Ø
Temperature: 0 ~ 60°C
Ø
Humidity: 5 ~ 95 %(RH)
Operation Environmental Conditions: (outdoor version,
RT)
Ø Temperature:
-20 ~ 70°C
Ø Humidity: 5 ~ 95% (RH)