The Mini MEX-1/MTX-1 Jack Panel is a centralized
termination point for digital equipment at E1(2.048Mbps)/
MTX-1

(1.544Mbps) digital signal bit rate to provide
the interface for monitoring, inspection, bypass,
transferring purpose.
Each circuit in the Mini MEX-1/ MTX-1 Jack Panel
is independent, users may choose the proper capacity
as needed to reduce the initial set-up cost. And
for easy maintenance, the independent circuit module
can be replaced separately.
The MEX-1/ MTX-1 panel in 23" wide rack consists
of 84 circuit-module in the chassis, while 19”
wide rack consists of 64 circuit-module.
Features
Four-circuit, plug-in
module
Replicable,
single-circuit jack card
Red, yellow, and
green LEDs
Front and rear
fanning strips and wire-wrap pin block
Specifications
Electrical
- MEX-1/MTX-1
Power Requirement: -48V DC
Characteristic Impedance:120Ω+/-
5%/100Ω+/-
5%
Return Loss: Better than -26dB
(@1024KHz/772KHz)
Insertion Loss: Better than 0.2dB
(@1024KHz/772KHz)
Monitor Level: Below signal level
20dB+/-1dB
Cross Talk: Better than -60dB
(@1.024MHz/772KHz)
Contact Resistance: Less than 0.02Ω(Initial)
Insulation Resistance: More than
10,000MΩ
at DC500V
Dielectric Withstanding Voltage:
500V AC
Insertion Force: 7lbs Max.
(Average) Withdrawal Force:
1.5lbs Min.
(Average) Life: 20000 cycles Min.
Vibration: Per MIL-STD-202F,
method 201A
Shock: Per MIL-STD-202, method
107D
Environmental
Thermal Limits: -40℃~65℃
Thermal Shock: Per MIL-STD-202,
method 107D
Humidity: 0%~95%
Moisture Resistance: Per
MIL-STD-202F, method 106E
Salt Spay: Per MIL-STD-202F,
method 101D
Application
Used between two E1 equipment
such as M13 and DLC, E1/T1 and end user, and two
E1/T1 in station.

|